Specifications
General characteristics | |
---|---|
Type of | wall split system |
Main modes | cooling / heating |
Power in cooling mode | 2100 watts |
Power in heating mode | 2350 W |
Heating power consumption | 600 W |
Cooling power consumption | 690 W |
Fresh air mode | not |
Additional Modes | ventilation mode (without cooling and heating), automatic mode, self-diagnosis of faults |
Drainage Mode | there is |
Control | |
Remote control | there is |
On / Off Timer | there is |
Dimensions | |
Indoor unit split system or mobile air conditioner (WxHxD) | 84.8x29x20.4 cmn |
Split system outdoor unit or window air conditioner (WxHxD) | 65x53x23 cmn |
General | |
Indoor unit noise level (min / max) | 25 dB / 37 dB |
Refrigerant type | R 410A |
Phase | single phase |
Fine air filters | not |
Fan speed adjustment | there is |
Other functions and features | the ability to adjust the direction of the air flow, the memory function settings, warm start |
Service area | 18 square meters m |
Comments about the air conditioner Panasonic CS-YW7MKD
Virtues
- Relatively inexpensive, considering current prices.
- Quite quiet external unit (although for me it does not matter).
disadvantages
- The main thing is reliability (it broke down in the second year after installation). Shaky cheap plastic (which is normal for this price). The noise of the indoor unit, and at low speeds (the creaking of the curtains), on large ones is not so noticeable.
Comment
I chose (although it's difficult to call it a choice) from what it was. Considering the kondeya class (and not the price for which it took, wound up by our sellers) all the talk about plastic, a simple console, etc. — baby talk, everything corresponds to its class. The biggest disappointment is a breakdown next year (work 40 minutes - 1.5 hours, then shutdown, Timer indicator blinking), although the 1st season worked fine. Rummaged through the Internet and realized that I was not the only one. I do not even think about repairs, because Season and hemorrhoids can not be gathered (and not worth it a bucket of costs). But he came out of the situation as follows: if the condo is not turned on from the console, but by a button on the internal unit, it will not turn off (though it is impossible to adjust the temperature and other settings - it will not be cut down again, so I don’t touch the console at all), and I use the heat : turned on the button and he hrenachit all the money without stopping until you turn it off. Everything is better than to stay in the heat without him.
In short, before taking, hammer in the search engine: the Panasonic air conditioner is turned off, the timer light is flashing - read and everything will become clear.
Hope was helpful.
Anonim 2012-07-13 Evaluation 1
Virtues
- Cools quickly and efficiently. the ratio of price and quality is almost identical, if only there is not one thing ....
disadvantages
- The biggest drawback is the direction of the air flow. The horizontal flap opens from bottom to top and air flows under it. Accordingly, it is impossible to direct the air flow parallel to the floor, it blows approximately at an angle of 60 degrees from the vertical.
Comment
If you still decide to buy this condo, then when installing, consider the orientation of the air flow. And it is better to choose a condo whose door opens from top to bottom, so that you can start a stream parallel to the floor. If it were not for this significant minus, then it would have turned out a great budgetary KND. The unsightly remote, the small display and the lack of backlighting are not considered flaws.
prostakov82, 2011-07-04 Evaluation 3
Virtues
- They say he does not kill the compressor ... When installed for 80-100% of the cost of kondeya, you will receive a 3-year warranty ...
disadvantages
- The device has a self-diagnosis function, but does not have error codes ... accordingly, the entire Internet writes about a flashing yellow-red timer light on the 48-50 minute of operation in cooling modes ...at this moment the condo turns off and then you will feel the unobtrusive service of the world giant.
Comment
According to the instructions, when the timer is blinking and not responding to commands from the remote control means calling the master, which Panasonic did not send to Russia. All services are busy, this case is known and uninteresting to them .. It’s written in the specifications that he has a self-test ... yes, he thought and decided to turn himself off, and he wouldn’t say the error code ... and that nobody knows with him ... in short .. they put three things themselves, according to all the elementary rules with evacuation. Two plow, the third does not plow, the warranty extended only when installed by the official .. that is, the price is X 2. Wild! They called third-party masters, watched the sniff, everything was normal, the pressure, oil tasted the color .. no track bends, the voltage was normal ... they say they should be removed and taken to the service .. so I'll take it off .. but there is no service. Panasonic has no service in Russia. Doubt? Find a phone from the Panas site, get through, and then having described the case, ask how much refrigeration primitivism is taken from you ... two months is easy ... and summer? How long is summer in Russia?
ali.brombel, 2012-07-15 Evaluation 1
Virtues
- Cheap, trouble-free.
disadvantages
- The names of the buttons on the remote have been erased. The Auto mode is not clear.
Comment
All those who have this model turned off and the timer light starts to blink - THIS IS 99% INSTALLER ERROR !!!!
There are several main reasons for blinking:
1. Lack of refrigerant in the system (it cools worse, see the upper tube of the external unit, if frost has appeared on it, it is necessary to refuel it)
2. Errors in the installation of the drainage system and also if the hose is clogged (because of this, it may also drip condensate from the indoor unit)
3. The radiator of the indoor unit froze and as soon as the ice reaches the sensor, the system turns off, the timer blinks. (there may be point 1 and 2)
If you refuel your system, be sure to keep the installer for at least 20 minutes with the air conditioner turned on so you can exclude point 1
I will not write about the fact that the wires can be confused, these are only the main reasons for the blinking of the timer. And I repeat once again, there is almost nothing to break in this system, all problems are associated only with the installer and his straight arms.
Gusev Alexander, 2014-07-17 Evaluation 5
Virtues
- Phenomenally low noise, price
disadvantages
- Not yet discovered
Comment
The surprisingly low noise level of both units, and I do not have double-glazed windows, ordinary windows. Also very pleased with the democratic price. To all those who write that the console is uncomfortable, small, and so on ... that is simply curved or blind, in my opinion, the console is simple as a Kalashnikov machine gun, and rightly so. In general, condo inexpensive, silent and without any dubious supposedly very necessary options.
Mamontov Sergey, 2013-07-08 Evaluation 5
Virtues
- as such there is no, it works like a normal start-stop conditioner should work
disadvantages
- there is no critical, however, see comment
Comment
Detailed photos: http://yadi.sk/d/2rxwDdGZ650m4
Exploitation:
- The intensity of the air flow. Min Blowing intensity at 1st speed is pretty decent, it would be more comfortable if the flow was smaller. The 3rd maximum is already too strong and noisy, but the worse thing is that this 3rd speed is turned on in the Auto fan speed mode always, regardless of the difference of the set temperature and air t, I don’t use Auto Fan speed for this.
- Directions of air flow (for extreme operating positions of the sash, see photo 417.418): it cannot blow horizontally or vertically. Nevertheless, you can turn the sash with your hands, having achieved the vertical direction of the blower, but after off / on. Kondishin from the remote sash exhibited in the factory position.
- The published noise. In my case, the most annoying is the buzz of the internal. block the first 40s when the compressor is turned on - the peak of the buzz falls on 10-30s, after 40s completely passes. The buzz comes from the vaporizer. My guess is that the short distance of the route is 1.5m, which is why some not quite normalized processes with pressure / evaporation / condensation of the refrigerant occur at start-up, and the evaporator acts as a resonator, and the installation instructions indicate the min .3m track ... A version that vibration is spreading through the tubes from the ext. the block was not confirmed because I listened to the external unit and tried to grope for vibrations - I did not find anything released when the compressor was started.
Another of the noises: the click of the compressor control relay; the crackle of the case; easy rustling of the fan motor at the first speed, at higher speeds - the noise from the air already appears. flow.
The outdoor unit does not bother (as if it were not without my modifications I will not say), in the next room only at night you hear a rumble transmitted through the wall.
Conclusion: I do not think that competitors in the correlative price range can offer something better - the same China everywhere.
Full comment here: http://forum.ixbt.com/topic.cgi?id=47:11323-145#4357
Ko Andrew, 2013-06-24 Evaluation 3
Video review air conditioner Panasonic CS-YW7MKD