EVAN Warmos-IV-5
Characteristics of EVAN Warmos-IV-5
- Power 5 kW.
- A possibility of use as the heat carrier both water, and non-freezing liquids.
- TENY from stainless steel of production Backer.
- Independent emergency shutdown circuit.
- Set the temperature of the coolant with an accuracy of 1 degree, in the range from +5 to + 85 ° C.
- The extension of the temperature range from +5 to +85 ° C makes it possible to use the boiler in the modes: "warm floor" and "anti-freezing".
- The ability to limit the power of the boiler. Three steps - each step 1/3 of boiler capacity.
- Time delay on / off power steps.
- Automatic selection of the required number of steps for regulating the set temperature of the coolant (due to the replacement of a mechanical thermostat with a thermal sensor with electronic thermal control).
- Light indicators that display all the necessary information - display of the current temperature in the range from 0 to +90 ° C.
- When starting the boiler at temperatures below 0 (the case of antifreeze fluid in the system), the boiler is maintained, the indicator shows “-0”.
- The mode "Control of the boiler according to the air temperature in the room" is displayed on the indicator by a flashing point.
- Rotation of heaters with each switch on the boiler in the "heating" mode.
- Block for connecting the circulating pump and air temperature sensor.
- Guaranteed operation of the device when the supply voltage deviates + -10% of the nominal value of the network.
- Indication of emergency codes
WARMOS-IV-5 operates in the extended coolant temperature range from +5 to + 85 ° C. Due to this, you can additionally use it in such modes as: “Warm floor” and “Anti-freezing”:
In the “floor heating” mode WARMOS-IV-5 directly connects to the floor heating system.
In the “Anti-freezing” mode, the boiler saves energy by operating from +5 to + 15 ° C. This is convenient when people leave the room for a long time.
When an emergency situation occurs, the panel displays codes that signal if:
- The temperature sensor for coolant temperature monitoring has broken (code E1);
- a short circuit temperature sensor temperature control (E2);
- the coolant warmed up above + 84 ° C (E3);
- the coolant warmed up above + 90 ° C (FF).
Additional safety is provided by an independent emergency shutdown circuit.
You easily set the desired coolant temperature from +5 to + 85 ° C with an accuracy of 1 degree. Power levels are selected in automatic mode - the boiler itself determines the optimal number of stages. At the same time, the possibility of manual power control remains.
Reviews of EVAN Warmos-IV-5
stylish design,
control is simple,
GSM connectivity with voice and internet control.