Fluke TiS75
detailed information
9.9 / 10
Rating
Fluke TiS75 Specifications
Main characteristics | |
Spatial resolution (IFOV) | 2.0 mrad |
Detector resolution | 320 x 240 |
line of sight | 35,7 ° × 26,8 ° |
The ratio of the distance to the size of the measured area | 504:1 |
Wireless connection | Yes |
IR-Fusion® technology | |
AutoBlend ™ mode | 5 presets (0%, 25%, 50%, 75%, 100%) |
Picture-In-Picture Mode (PIP - Picture-in-Picture) | 5 presets (0%, 25%, 50%, 75%, 100%) |
Focusing system | Manual focus, the minimum focusing distance is 0.15 m (6 inches) |
Shockproof display | 3.5-inch horizontal LCD display, 320 x 240 |
Robust, ergonomic design for one-handed operation | Yes |
Thermal Sensitivity (NETD) | ≤ 0.08 ° C at an object temperature of 30 ° C (80 mK) |
Measured temperature range (not calibrated below -10 ° C) | -20 to +550 ° C (-4 to 1022 ° F) |
level and sensitivity | Smooth automatic and manual scaling |
Fast automatic switching between manual and automatic modes | Yes |
Fast automatic scale change in manual mode | Yes |
Minimum interval (in manual mode) | 2.5 ° C |
Minimum interval (automatic mode) | 5 ° C |
Built-in digital camera (visible light) | 5 Mp |
Frame frequency | 9 Hz or 30 Hz |
Laser pointer | Yes |
Data storage and image capture | |
Expandable SD card storage device | 4 GB internal memory and removable Micro SD 4 GB memory card |
The mechanism of fixing, viewing and saving images | The ability to capture, view and save images with one hand |
Image File Formats | Without radiometric data (.bmp) or (.jpeg) or with full radiometric data (.is2); No special software is required for working with files without radiometric data (.bmp, .jpg) |
View the contents of memory | View thumbnails |
Software | SmartView® software - for complete analysis and reporting |
Exporting data to files using SmartView® software in formats | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF and TIFF |
Voice annotation | Yes, using a Bluetooth headset (sold separately) |
IR-PhotoNotes ™ | Yes (3 pictures) |
Standard video | Yes |
Video recording with radiometric data | Yes |
Video file formats | Without radiometric data (MPEG - .AVI coding) and with complete radiometric data (.IS3) |
Streaming video (remote display) | Yes |
Battery | |
Batteries (replaceable, rechargeable) | Two lithium-ion "intelligent" rechargeable batteries with a five-segment LED indicator to display the charge level |
Battery life | More than four hours |
Battery charge time | 2.5 hours to full charge |
Battery charge method | Charger for two batteries or charge directly in the imager |
AC operation | The device can operate on AC power (from 100 to 240 V, 50/60 Hz) with the included power adapter |
Temperature measurement | |
Accuracy | ± 2 ° C or 2% (at a nominal temperature of 25 ° C, a larger value is selected) |
Correction of emissivity on the screen | Yes (by number and table) |
Temperature compensation of the background reflection on the screen | Yes |
Screen ratio adjustment | Yes |
Color palettes | |
Standard palettes | 8: "Hot Metal", blue-red, high-contrast, yellow, yellow inverted, heated metal colors, grayscale, gray gradations inverted |
Ultra Contrast ™ Palettes | 8: Ultra Hot Metal, Ultra Blue-Red, Ultra High Contrast, Ultra Ultra Yellow, Ultra Inverted Yellow, Ultra Metal Heated Colors, Ultra Grayscale, Ultra Inverted Grayscale |
General characteristics | |
Color alarm (temperature alarm) | High temperature, low temperature, isotherms |
IR spectrum | 7.5 to 14 microns |
Operating temperature range | -10 to +50 ° C (14 to 122 ° F) |
Storage temperature | -20 to +50 ° C (-4 to 122 ° F) |
Relative humidity | 10% to 95% (non-condensing) |
Temperature measurement at the center point | Yes |
Point temperature measurement | Yes |
User-defined point markers | ="3" |
Central rectangle | The rectangle of measurements adjusted on width and height with speed. MIN-MAX-MEDIUM |
Safety standards | EN 61010-1: without category, pollution degree 2, EN 60825-1: class 2, EN 60529, EN 62133 (lithium battery) |
Electromagnetic compatibility | EN 61326-1: 2006, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3 |
C Tick certified (in Australia and New Zealand) | IEC / EN 61326-1 |
US FCC | EN61326-1; FCC Part 5, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3 |
Vibration and shock resistance | 2G, IEC 68-2-6 and 25G, IEC 68-2-29 |
Drop Resistance | Designed to withstand a fall from a height of 2 m (6.5 feet) |
Dimensions (H × W × D) | 26.7 x 10.1 x 14.5 mm (10.5 x 4.0 x 5.7 inches) |
Weight (with battery) | With a fixed focus of 0.72 kg (1.6 lbs), with a manual focus of 0.77 kg (1.7 lbs) |
Enclosure class | IP54 (limited dust protection; splash protection from any direction) |
Warranty | Two years (standard), extended warranty agreements possible |
Recommended Calibration Period | Two years (during normal operation and normal depreciation) |
Supported Languages | English, Hungarian, Spanish, Italian, Chinese (Traditional), Chinese (Simplified), Korean, German, Dutch, Polish, Portuguese, Russian, Turkish, Finnish, French, Czech, Swedish and Japanese |
Fluke TiS75 is selected in rating: